Direkt zum Inhalt springen
login.png Login join.png Register    |
de | en
MyTUM-Portal
Technical University of Munich

Technical University of Munich

Sitemap > Media > Press releases > High-resolution method for computed nano-tomography developed
up   Back to  News Board    previous   Browse in News  next    

Advanced imaging for bone research and materials science:

High-resolution method for computed nano-tomography developed

Prof. Dr. Franz Pfeiffer

22.09.2010, Press releases

A novel nano-tomography method developed by a team of researchers from the Technische Universität München (TUM), the Paul Scherrer Institute (PSI) and the ETH Zurich opens the door to computed tomography examinations of minute structures at nanometer resolutions. The new method makes possible, for example, three-dimensional internal imaging of fragile bone structures. The first nano-CT images generated with this procedure will be published in the renowned journal Nature on September 23, 2010. This new technique will facilitate advances in both life sciences and materials sciences.

Osteoporosis, a medical condition in which bones become brittle and fragile from a loss of density, is among the most common diseases in aging bones: In Germany around a quarter of the population aged over 50 is affected. Patients' bone material shrinks rapidly, leading to a significantly increased risk of fracture. In clinical research to date, osteoporosis is diagnosed almost exclusively by establishing an overall reduction in bone density. This approach, however, gives little information about the associated, and equally important, local structure and bone density changes. Franz Pfeiffer, TUM professor for Biomedical Physics and head of the research team, has resolved the dilemma: “With our newly developed nano-CT method it is now possible to visualize the bone structure and density changes at high resolutions and in 3D. This enables us to do research on structural changes related to osteoporosis on a nanoscale and thus develop better therapeutic approaches.”

During development, Pfeiffer’s team built on X-ray computed tomography (CT). The principle is well established – CT scanners are used every day in hospitals and medical practices for the diagnostic screening of the human body. In the process the human body is X-rayed while a detector records from different angles how much radiation is being absorbed. In principle it is nothing more than taking multiple X-ray pictures from various directions. A number of such pictures are then used to generate digital 3D images of the body's interior using image processing.

The newly developed method measures not only the overall beam intensity absorbed by the object under examination at each angle, but also those parts of the X-ray beam that are deflected in different directions – “diffracted” in the language of physics. Such a diffraction pattern is generated for every point in the sample. This supplies additional information about the exact nanostructure, as X-ray radiation is particularly sensitive to the tiniest of structural changes. “Because we have to take and process so many individual pictures with extreme precision, it was particularly important during the implementation of the method to use high-brilliance X-ray radiation and fast, low-noise pixel detectors – both available at the Swiss Light Source (SLS),” says Oliver Bunk, who was responsible for the requisite experimental setup at the PSI synchrotron facilities in Switzerland.

The diffraction patterns are then processed using an algorithm developed by the team. TUM researcher Martin Dierolf, lead author of the Nature article, explains: “We developed an image reconstruction algorithm that generates a high-resolution, three-dimensional image of the sample using over one hundred thousand diffraction patterns. This algorithm takes into account not only classical X-ray absorption, but also the significantly more sensitive phase shift of the X-rays.” A showcase example of the new technique was the examination of a 25-micrometer, superfine bone specimen of a laboratory mouse – with surprisingly exact results. The so-called phase contrast CT pictures show even smallest variations in the specimen’s bone density with extremely high precision: Cross-sections of cavities where bone cells reside and their roughly 100 nanometer-fine interconnection network are clearly visible.

“Although the new nano-CT procedure does not achieve the spatial resolution currently available in electron microscopy, it can – because of the high penetration of X-rays – generate three-dimensional tomography images of bone samples,” comments Roger Wepf, director of the Electron Microscopy Center of the ETH Zurich (EMEZ). “Furthermore, the new nano-CT procedure stands out with its high precision bone density measurement capacity, which is particularly important in bone research.” This method will open the door to more precise studies on the early phase of osteoporosis, in particular, and evaluation of the therapeutic outcomes of various treatments in clinical studies.

The new technique is also very interesting for non-medical applications: Further fields of application include the development of new materials in materials science or in the characterization of semiconductor components. Ultimately, the nano-CT procedure may also be transferred to novel, laser-based X-ray sources, such as the ones currently under development at the Cluster of Excellence “Munich-Centre for Advanced Photonics” (MAP) and at the recently approved large-scale research project “Centre for Advanced Laser Applications” (CALA) on the TUM-Campus Garching near Munich.

Original publication:

Martin Dierolf, Andreas Menzel, Pierre Thibault, Philipp Schneider, Cameron M. Kewish, Roger Wepf, Oliver Bunk, Franz Pfeiffer: “Ptychographic X-Ray Computed Tomography at the Nano-Scale”. Nature, 467, 436-439, 23. September 2010 – DOI: 10.1038/nature09419

Images for download

Animation

This animation shows the first nano-CT pictures of a bone sample with a diameter of about 25 micrometers. Clearly resolved are the fine, approximately 100-nanometer channels (canaliculi) that make up the interconnective network between the bone cells (osteocytes).

Contacts:

Prof. Franz Pfeiffer
Chair of Biomedical Physics Technische Universität München
James-Franck-Straße 1 85748 Garching, Germany 
Tel.: +49 89 289 12551, Fax: +49 89 289 12548 
E-Mail - Internet

Dr. Oliver Bunk 
Laboratory for Macromolecules and Bioimaging 
Paul Scherrer Institute
3232 Villigen PSI, Switzerland 
Tel.: +41 56 310 3077
E-Mail - Internet

Dr. Roger Albert Wepf 
EMEZ – Electron Microscopy ETH Zurich
ETH Zurich 
Wolfgang-Pauli-Str. 16 8093 Zurich, Switzerland
Tel: +41 44 633 45 58 
E-Mail - Internet

Kontakt: presse@tum.de

More Information

100920_nanoCT_PW_DE.pdf Druckversion der Presseinformation (DE), (Type: application/pdf, Size: 230.5 kB) Save attachment
100920_nanoCT_PW_EN.pdf Printable version of the press release (EN), (Type: application/pdf, Size: 230.1 kB) Save attachment

Corporate Communications Center

Media Relations Team
Arcisstr. 19
80333 München

Tel.: +49.89.289.22778
Fax: +49.89.289.23388

 presse@tum.de

Contact

Todays events

no events today.

Calendar of events